+32 2 559 77 22

Please download the user guide for the following informations:


| Wheel position | Dosing period (time between strokes) | Refilling frequency vs Cartridge content | 
|---|---|---|
| 0 | External | |
| 1 | 24 h | 6 months | 
| 2 | 16 h | 4 months | 
| 3 | 12 h | 3 months | 
| 4 | 8 h | 2 months | 
| 5 | 4 h | 1 month | 
| 6 | 2 h | 15 days | 
| 7 | 1 h | 7 days | 
| 8 | 0,5 h | – | 
| 9 | 0,25 h | – | 
| Wheel position | Dosing period (time between strokes) | Refilling frequency vs Cartridge content | 
|---|---|---|
| 0 | External | |
| 1 | 24 h | 12 months | 
| 2 | 16 h | 8 months | 
| 3 | 12 h | 6 months | 
| 4 | 8 h | 4 months | 
| 5 | 4 h | 2 months | 
| 6 | 2 h | 1 month | 
| 7 | 1 h | 15 days | 
| 8 | 0,5 h | 7 days | 
| 9 | 0,25 h | – | 
| Wheel position | Dosing period (time between strokes) | Refilling frequency vs Cartridge content | 
|---|---|---|
| 0 | External | |
| 1 | 24 h | NA | 
| 2 | 16 h | NA | 
| 3 | 12 h | 12 months | 
| 4 | 8 h | 8 months | 
| 5 | 4 h | 4 months | 
| 6 | 2 h | 2 months | 
| 7 | 1 h | 1 month | 
| 8 | 0,5 h | 15 days | 
| 9 | 0,25 h | 7 days | 
| Parameter | Situation | Color | 
|---|---|---|
| Gearbox-Motor | Damaged – Broken |   Red | 
| Battery | Empty |   Yellow | 
| Vibration / T°/Pump | Abnormal — Vacum problem |   Blue | 
| Touchpad | Test |   Green | 
											
																							Only for MEMOLUB® VISIO EP: Disconnect the power plug
											
																							Open (fingers on ribs)
											
																							Prime MEMOLUB®
											
																							Insert new battery pack and seal
											
																							Squeeze air out of cartridge
											
																							Replace cartridge
											
																							Close and lock (fingers on ribs)
											
																							Prime lube point and remove nipple
											
																							Screw in Memo using threadlocker
											
																							Choose the dosing setting
											
																							Install MEMOLUB® on the base module
											
																							Only for MEMOLUB® VISIO EP: Connect the power plug
											
																							Check with the touchpad
											
																							Prime lube point and remove nipple
											
																							Secure bracket
											
																							Install the base module and F1/4 fitting
											
																							Screw BSP 1/8 fitting
											
																							Cut hose to required size
											
																							Insert hose into quick fitting
											
																							Insert hose into quick fitting
											
																							Choose the dosing setting
											
																							Install MEMOLUB® on the base module
											
																							Only for MEMOLUB® VISIO EP: Connect the power plug
											
																							Check with the touchpad
											
																							Prime lube point and remove nipple
											
																							Secure bracket
											
																							Install the base module and F1/4 fitting
											
																							Screw BSP 1/8 fitting
											
																							Cut hose to required size
											
																							Insert hoses into quick fittings
											
																							Insert hoses into quick fitting
											
																							Choose the dosing setting
											
																							Install MEMOLUB® on the base module
											
																							Only for MEMOLUB® VISIO EP: Connect the power plug
											
																							Check with the touchpad
											
																							Check with the touchpad
											
																							Check regularly
					Copyright © 2025 MEMOLUB®
					 | 
					Design by Generis
					 | 
					Produced with the support of