Setting of MEMO through combination of 3 plastic rings:
50mm 44mm 38mm
Expulsions per day | Daily output (cc) | Cartridge life (Month) | Memo adjustment |
---|---|---|---|
0.5 | 0.3 | 12 | |
1 | 0.6 | 6 | |
1.5 | 0.9 | 4 | |
2 | 1.2 | 3 |
Expulsions per day | Daily output in cc | Cartridge life (Month) | Memo adjusments |
---|---|---|---|
0.5 | 0.3 | 24* | |
1 | 0.6 | 12 | |
1.5 | 0.9 | 8 | |
2 | 1.2 | 6 | |
4 | 2.4 | 3 | |
12 | 7.2 | 1 | |
24 | 14.4 | 1/2 |
* Only with MEMOLUB® HPS
Expulsions per day | Daily output in cc | Cartridge life (Month) | Memo adjusments |
---|---|---|---|
1.5 | 0.9 | 16 | |
2 | 1.2 | 12 | |
4 | 2.4 | 6 | |
12 | 7.2 | 2 | |
24 | 14.4 | 1 |
Open (fingers on ribs)
Prime MEMOLUB®
Insert new battery pack and seal
Squeeze air out of cartridge
Replace cartridge
Close and lock (fingers on ribs)
Prime lube point and remove nipple
Screw in Memo using threadlocker
Install MEMOLUB® on Memo
MEMOLUB® works immediately
Prime lube point and remove nipple
Secure bracket
Install Memo and F1/4 fitting
Screw BSP 1/8 fitting
Cut hose to required size
Insert hose into quick fitting
Insert hose into quick fitting
Install MEMOLUB® on Memo
MEMOLUB® works immediately
Prime lube point and remove nipple
Secure bracket
Install Memo and F1/4 fitting
Screw BSP 1/8 fitting
Cut hose to required size
Insert hose into quick fitting
Insert hose into quick fitting
Install MEMOLUB® on Memo
MEMOLUB® works immediately
To check unit: unscrew and screw again
Check regularly